Skip to content
Consultation Partner

Existing buildings & renovation. With minimal effort.

In an existing building, every intervention counts. The heating paint needs only minimal work: the electrician lays the supply cables, and the technology takes up very little space.

Renovated period apartment with stucco and herringbone parquet (visualisation)
Retrofit

Minimal effort in existing buildings

A new heating system in an existing building usually means major work: boiler, boiler room, water pipes, often a new screed. The heating paint needs only minimal work. Every room is its own heating system with its own control.

  • The electrician lays the supply cables
  • All technology (transformer, controls) in a single-family home on max. 1 m², approx. 10 cm high
  • If desired, installed entirely in the ceiling – with inspection openings
  • Floor build-up stays intact
  • Can be done room by room – in stages, too
Comparison

What you no longer need.

What you no longer need

Boiler
Tank & storage
Water pipes
Radiators
Chimney
Maintenance

What stays

Supply line
24 V transformer
Heating surface

Every room is its own heating system with its own control.

Masonry

Every wall is planned individually.

In existing buildings, material and layer build-up determine the design. CARBON4® plans for all typical construction methods:

Brick · clinker · fired brick

Solid & heat-retaining

Often uninsulated – thermal decoupling in front of the heating surface.

Sandstone

Historic

High capillary moisture absorption; vapour-permeable internal insulation, e.g. wood fibreboard.

Timber framing

Timber & infill

Vapour-permeable systems matched to the building physics, with clay or lime plaster.

Natural & rubble stone

Keeping an eye on damp

Renovation and lime plaster systems help the masonry dry out.

Do I need insulation in an older building?
Thermal decoupling must always be provided between the masonry and the heating surface, for example internal insulation. It prevents heat from escaping into the solid wall and shortens the heat-up time.
Is the heating paint suitable for listed buildings?
Yes. It is applied on site, follows uneven or curved surfaces too, and requires only minimal intervention in the building fabric. In listed buildings, vapour-permeable lime and restoration plasters are preferred.
Are there subsidies for renovation?
In Germany, a CARBON4® surface heating system can be eligible for funding as part of a qualified energy-efficient renovation (Effizienzhaus 40/55) – if heating and PV are converted together, the building envelope is improved and the measure is supervised by an accredited energy consultant. Eligibility must always be checked for each project.
Am I allowed to heat with electricity in a rented older building?
In Germany, § 71d GEG sets special requirements for structural thermal insulation for electric surface heating in rented existing buildings. Clarify this in the initial consultation – we will check it for your property.

Your project. Individually planned.

Initial consultation of 30–45 minutes, by phone or video call.

Request a consultation →Call