Skip to content
Consultation Partner

Floor heating. Warmth from below.

The heating paint also works in the floor – on screed or drywall, for example in the bathroom under tiles. It remains only 0.4 to 0.6 mm thin.

Family playing barefoot on the warm wooden floor in a bright living room (visualisation)
Why the floor

Warm feet, invisible technology

In the floor, too, the heating paint is only 0.4 to 0.6 mm thin. It is applied to the primed screed or to a drywall board and finished with filler or levelling compound. The floor covering follows.

It is particularly well suited under tiles and natural stone – in the bathroom, for example. Other floor coverings are possible if the manufacturer approves them for underfloor heating.

CARBON4® Complete is not suitable for floors – the system board is too soft for that. That is why the heating paint is always applied directly on floors.

The floor must not be loaded while it dries. Drying is comparatively quick: the surface is put into operation straight away and dries electrically.

  • Written screed approval before work begins
  • Floor coverings with a thermal resistance of up to 0.15 m²K/W
  • No Complete on floors – too soft
  • Fast electrical drying – do not load the floor meanwhile
Build-up

Three ways into the floor.

Screed

On the screed

  1. Concrete subfloor
  2. Levelling / insulation
  3. Screed
  4. Screed primer
  5. Heating paint
  6. Levelling compound / waterproofing / primer
  7. Floor covering
Drywall

On OSB board

  1. Concrete subfloor
  2. PE or aluminium foil
  3. Insulation, impact sound
  4. OSB board
  5. Primer
  6. Heating paint
  7. Mesh and levelling compound
  8. Floor covering
Wet area

In the bathroom

  1. Screed
  2. Primer
  3. Heating paint
  4. Waterproofing*
  5. Flexible tile adhesive
  6. Tiles

* Only electrically non-conductive waterproofing, approved in advance by CARBON4®.

Which floor coverings are suitable?
Tiles and natural stone are usually suitable without restriction. Laminate, parquet, vinyl, cork and linoleum only if the manufacturer expressly approves them for underfloor heating. Thick carpets slow down heat emission.
What is screed approval?
A written confirmation from the person responsible for the construction that the screed has been laid professionally, is suitable for underfloor heating and ready for covering, and has no hollow spots or defects. Without it, work does not begin.
Does it work in the bathroom too?
Yes. In wet areas the heating paint is applied to the primed screed and covered with waterproofing. Only electrically non-conductive waterproofing products approved in advance by CARBON4® may be used.
How long does the floor need to dry?
Not long: the surface is put into operation straight away and dries electrically. The floor must not be loaded while it dries.
Why does CARBON4® nevertheless often recommend ceiling and wall?
Ceilings and walls stay free of furniture and rugs and are independent of the floor covering. The floor is ideal where warm feet matter – in the bathroom, for example.

Your project. Individually planned.

Initial consultation of 30–45 minutes, by phone or video call.

Request a consultation →Call