BasicsWhat is heating paint?
A conductive coating applied between two copper strips on a wall, ceiling or floor. When 24-volt current flows through it, the entire surface warms up and gives off radiant heat to the room.
BasicsWill the heating be visible afterwards?
No. The coating is only 0.4 to 0.6 mm thin and is finished with mineral filler and then with paint, plaster or tiles.
BasicsIs heating paint safe for your health?
The heat emitted is in the infrared range of roughly 0.8 to 50 µm, similar to the warmth of the sun. According to the safety data sheet (section 2.3), the heating paint contains no components ≥ 0.1% classified as PBT or vPvB. Electromagnetic compatibility was independently tested by Carinthia University of Applied Sciences in Villach.
BasicsWhat is the difference between radiant heat and convection?
Convection heaters mainly heat the air, which then circulates. Radiant heat directly warms surfaces, furniture and people – like the sun. As a result, there is hardly any air movement and cold wall surfaces are avoided.
BasicsWhat is CARBON4® Complete?
The prefabricated system version: system boards for walls and ceilings that combine insulation and heating paint. Active heating boards are called Complete, passive filler boards Pure. Only Pure boards may be cut to size.
InstallationWho installs the heating paint?
Only certified CARBON4® partner companies. The 230-volt side is always connected by a licensed electrical contractor.
InstallationCan I paint or tile over the heating paint?
Yes. The heating surface is finished with at least 1 mm of mineral filler (recommended: fully reinforced with mesh). After that, paint, plaster or tiles are possible – according to the manufacturer's specifications and with CARBON4® approval.
InstallationWhich ceilings are suitable for ceiling heating?
Solid ceilings with a sound, primed substrate, drywall ceilings with filled and reinforced joints, and suspended ceilings. For suspended ceilings, the prefabricated CARBON4® Complete system is also available.
InstallationWhy does wall heating need thermal decoupling?
Without a separating layer, a considerable part of the heat would flow into the masonry. That costs energy and lengthens the heat-up time. Options include insulation boards at least 2 cm thick, insulating and thermal plasters or other interior insulation. The exception is damp remediation – there the heat is meant to go into the masonry.
InstallationDo you need a plant room?
No. All you need is a supply line prepared by the electrician and space for the transformer – centrally in a technical cabinet, in the basement or attic, or in the room itself, surface-mounted or flush-mounted.
InstallationCan the heating paint be used in floors?
Yes, for example in the bathroom under tiles. This requires written screed approval, and only floor coverings approved for underfloor heating with a thermal resistance of up to 0.15 m²K/W may be used. CARBON4® primarily recommends ceilings and walls.
Operation & safetyHow hot does the surface get?
The rated limit temperature of the heating paint is 60 °C. In operation, the room thermostat controls the surface as required; in damp remediation, the masonry is warmed to around 30 °C.
Operation & safetyCan I drill into a heated wall?
Yes. You can drill into the heating surface up to the size of a socket box; nails and wall plugs are no problem. The only thing to watch out for is the copper strips – your final documentation shows where they run.
Operation & safetyHeating paint, heated wall paint – what is the difference?
They usually mean the same thing: an electrically conductive coating applied between two copper strips that warms the surface evenly. CARBON4® calls its product heating paint. Beneath filler and paint it is invisible – you remain free to choose the visible wall paint on top.
Operation & safetyHow safe are 24 volts?
Only low voltage of 24 volts is present in the room. The 230-volt side ends at the transformer and is connected exclusively by a licensed electrical contractor and protected with a 16 A (type C) breaker.
Costs & fundingIs heating with electricity expensive?
There is no blanket answer. The installed output says nothing about annual consumption. What matters is the building's heating demand, a suitable design, the controls and the actual heating times. That is why we calculate every project individually.
Costs & fundingWhat does it cost to install heating paint?
That depends on the area, the substrate, the number of rooms and the electrical planning. After the initial consultation, you receive a quote with a transparent breakdown of all components.
Costs & fundingIs funding available for renovation?
In Germany, a CARBON4® surface heating system can be eligible for funding as part of a qualified energy-efficient renovation (Effizienzhaus 40/55) – if heating and PV are converted together, the building envelope is improved and the measure is supervised by an accredited energy consultant. Eligibility must always be checked for each project.
Costs & fundingDoes the heating paint comply with the Building Energy Act (GEG)?
According to CARBON4®, the surface heating systems can be used in compliance with the GEG in well-insulated buildings in combination with photovoltaics and ventilation with heat recovery. Electric surface heating is additionally subject to § 71d GEG. We check the requirements for your project.
DampHow does damp remediation with heat work?
The heating paint is applied directly to the affected wall without an insulation layer so that the heat goes into the masonry. At around 30 °C the moisture evaporates, the surface stays warm and condensation no longer forms.
DampWhere is the heating paint applied in the case of rising damp?
As a 40 to 60 cm high strip just above the floor, directly on the masonry and deliberately without an insulation layer – where the damp rises in the masonry.
Glossary

Terms, briefly explained.

kW (kilowatt)
Output: how much heat a system can deliver at any given moment.
kWh (kilowatt hour)
Energy: output over time. The basis of your electricity bill.
Radiant heat
Infrared heat that warms surfaces and people directly instead of circulating the air.
Thermal decoupling
An insulating separating layer between masonry and heating surface, so heat goes into the room rather than into the wall.
24-volt low voltage
The voltage at which the heating paint operates in the room. The 230 V side ends at the transformer.
sd value
A measure of water vapour permeability. With sd < 0.1 m, the heating paint is vapour-permeable.
Running metre (lfm)
The length of a heating strip. Depending on the area, the strip width is between 40 and 80 cm.
CARBON4® Complete
A prefabricated board system that combines insulation and heating paint.

Your project. Individually planned.

Initial consultation of 30–45 minutes, by phone or video call.

Request a consultation →Call